13.28 Sense Condition (F0h: vendor specific)
see belowStatus1 1 1 1 0 0 0 0Command
- - - D - - - -Device/Head1 - 1 D - - - -Device/Head
- - - - - - - -Cylinder High- - - - - - - -Cylinder High
- - - - - - - -Cylinder Low- - - - - - - -Cylinder Low
- - - - - - - NSector Number- - - - - - - -Sector Number
V V V V V V V VSector Count- - - - - - - -Sector Count
see belowError0 0 0 0 0 0 0 1Feature
- - - - - - - -Data- - - - - - - -Data
7 6 5 4 3 2 1 0Register7 6 5 4 3 2 1 0Register
Command Block Input RegistersCommand Block Output Registers
V--V-VVV00V0V000
ERRIDXCORDRQDSCDFRDYBSYAMNT0NABT0IDN0UNCCRC
0123456701234567
Status RegisterError Register
Figure 111. Sense Condition Command (F0h)
The Sense Condition command is used to sense temperature in a device. This command is executable
without spinning up even if a device is started with No Spin Up option.
If this command is issued at the temperature out of range which is specified for operating condition, the
error might be returned with IDN bit 1.
Not recommendable condition for start up. If over stressed condition is detected,
this bit will be set to one.
N
Temperature is higher than 107°CFFh
Temperature is (Value/2–20)°C01h–FEh
Temperature is equal to or lower than –20°C00h
DescriptionValue
The Sector Count register contains result value.Sector Count
Input Parameters From The Device
The Feature register must be set to 01h. All other value are rejected with setting
ABORT bit in status register.
Feature
Output Parameters To The Device
Travelstar 48GH, 30GN & 15GN hard disk drive specifications
162