8. Slide the file module into the rack until it snaps into place. To slide the file
module out of the rack, press on the release latches 1.
Note: When you move the rack cabinet, or if you install the rack cabinet in a
vibration-prone area, insert the M6 screws 2 in the front of the file module.
Attach the Ethernet cables
About this task
This task assumes that your initial planning has determined where the Ethernet
cables are to be located. The Storwize V7000 Unified control enclosure requires at
least one and a maximum of two 1 Gbps Ethernet connections to each node
canister. Refer to Figure 50 on page 90, Figure 51 on page 90, Figure 52 on page 91,
and Figure 53 on page 92; also Table 45 on page 91 and Table 46 on page 92. For
the file modules, the first two 1 Gbps Ethernet ports labeled 5 and 6 in
Figure 54 on page 93 are used for internal communications between the file
modules. The third and fourth 1 Gbps Ethernet ports are used for management
ifs00031
Figure 48. Secure the cable management arm and the file module in the rack for shipping if
needed.
ifs00032
2
1
Storwize
V
7
0
0
0
U
n
if
ied
Storwize V7000 Unified
Figure 49. Install the front screws.
Chapter 5. Performing the hardware installation 89