EasyManua.ls Logo

IBM System/360 2050 - Page 112

IBM System/360 2050
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ROS
Channel
~
Address
Time
--.--
11.
Preu
START.
A24
CCW2,
cct,
AO
12.
Set
address keys 10
and
11
on,
9 off;
preu
ENTER.
CCW2,
cc1,
Al
13.
St0t
address
key
10
on,
9 and
11
off; press ENTER.
CCW2,
cc2,
cs
14.
Set
address
key
11 on,
9 and
10 off; press ENTER.
ccw2,
cc2
15.
Press ST ART.
BA2
16.
Press
START.
03C CCW2,
CC2,
AO
17.
Set
address keys 10 and
11
on,
9 off; press ENTER.
ccw2,
cc2,
Al
18.
Set
address
key
10 on,
9 and
11 off; press ENTER.
ccw2,
cc3,
cs
19.
Set
address
key
11
on,
9 and
10 off; press ENTER.
CCW2,
CC3,
AO
20.
Set address keys
10
and 11
on,
9 off; press ENTER.
ccw2,
cc3,
Al
21.
Set
address
key
10
on,
9 and
11
off; press ENTER.
cs
22.
Set
all
address keys off;
press ENTER.
23.
Press
START.
940
24.
Set
rate
switch
to
PROCESS.
Unit
Select
Routine
IOP211
Note:
Since
the
unit
select
routine
does
not
have
an
associated
ROS
routine,
it
is
impossible
to
ROS
stop
at
the
beginning
of unit
select.
The
following
pro-
cedure
will
stop
near
the
end
of
the
CCW2
routine,
step
through
to
the
end, and go
to
the
beginning
of
the
unit
select
routine.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
Set
ROS
address
BA2
in
the
storage
data
keys.
Set
ROS address
compare
switch
to
STOP.
Set
rate
switch
to
SINGLE
CYCLE.
ROS
~
Set address
key
11
on,
9 and
10 off; press ENTER.
Channel
Time
BA2
CCW2, CC2
Press ST
ART.
03C CCW2,
cc2,
AO
Set
address keys 10
and
11
on,
9 off; press ENTER. CCW2,
CC2,
Al
Set address
key
11
on,
9 and
10 off;
prea
ENTER. CCW2,
CC3
1
AO
Set
address
key
10
on,
9 and
11
off; press ENTER.
cs
Press
START.
940
Set
address
key
11
on,
9 and
10 off; press. ENTER. Unit
Sel,
CCO,
AO
Set
address keys 10
and
11
on,
9 off; press ENTER.
Unit
Sel,
CCO,
Al
Set
address
key
10
on,
9 and
11
off; press ENTER.
Unit
Sel,
CCl,
CS
Set
addreu
key
11
on,
9 and
10
off; press ENTER. Unit
Sel,
CC1,
AO
14.
15.
16.
17.
18.
19.
20.
ROS
Address
Set
address keys
10
and
11
on,
9 off; press ENTER.
Set
address
key
10
on,
9 and
11
off; press ENTER.
Set address keys 9
and
11
on,
10 off; press ENTER.
Set address keys 9
1
10,
and
11
on; press ENTER.
Set
address keys 9 and 10
on,
11
off; press ENTER.
Set
all
address keys off; press
ENTER.
Set
rate
switch
to
PROCESS,
End
Update
Routine
IOP209
Channel
Time
Unit
Sel,
CCI,
Al
Unit
Sel,
CC2,
CS
Unit
Sel,
ITD1
and
not
ITD2
Unit
Sel,
ITD2
111d
not
ITD3
Write
fetch
ITDl
and
not
In
Tag
ROS
Channel
1. Set
ROS
addreu
OOC
in
the
storage
data
keys.
2.
Set
ROS
address
compare
switch
to
STOP.
3.
Set
rate
switch
to
SINGLE
CYCLE.
4.
Set address
key
11
on,
9 and
10 off; press ENTER.
5. Press
START.
6.
Press
START.
7.
Set
address keys 10 and
11
on, 9 off; press ENTER.
8.
Set address
key
10
on,
9 and
11
off; press ENTER.
9.
Set address
key
11
on,
9 and
10 off; press ENTER.
10.
Press
START.
11. Press
START.
12. Set address keys 10
and
11
on,
9 off; press ENTER.
13. Set address
key
10 on, 9 and
11
off; press ENTER.
14.
Set
address
key
11
on,
9 and
10 off; press ENTER.
15. Press
START.
16.
Set
rate
switch
to
PROCESS.
Interrupt
Routine
IOP210
ROS
ooc
B4E
BBS
BC4
835
03C
~
Address
1. Set ROS address 004
in
the
storage
data
keys.
2.
Set
ROS
address
compare
switch
to
STOP.
004
3.
Set
rate
switch
to
SINGLE
CYCLE.
4.
Set
address
key
11
on,
9 and
10 off; press ENTER.
5.
Press
START.
AOO
6.
Press
START.
A99
7.
Set
address keys 10
and
11
on,
9 off; press ENTER.
Time
End Up,
cco
End Up, CCO,
AO
End Up, CCO,
Al
End
Up,
CCl,
CS
End Up,
CCl
End Up,
CCI,
AO
End Up,
CCl,
Al
End
Up,
CC2,
CS
End Up,
CC2
Channel
Time
Irpt,
cco
Irpt,
cco
Irpt,
cco,
AO
Irpt,
cco,
Al
Service
Checks,
Adjustment
and
Removal
Procedure
(3/71)
111

Table of Contents

Related product manuals