Operation
Storage
Storage
Location
Bits
Dato
location
Bits
Data
0084 0
SARP 18-15)
21-23
ROS
Cks
1-8
SAR
8-15
24
Protect
Tog
9
SAR
P 116-23)
25
LCS
Feature
10-17
SAR
16-23
26
log
Request
18
SARP 124-31)
27-31 Unused
19-26
SAR
24-31
OOA4
0-31 Unused
27
Unused
OOA8
0-31 Same as Location 009C
28-31
Byte
Stoh
OOAC
0 1/0 Mode
0088
0
IAR
P (8-15)
1-3
1/0 Register (P,
30,
31)
1-8
IAR
8-15
4-5
Interrupt Stats (Timer, Console)
9
JAR
P (16-231
6-8
L
Byte
Ctr
i0-17
JAR
16-23
9-11
M Byte
Ctr
18
JAR? (24-31)
12-16 F Register
19-26
IAR
24-31
17
Q Register
008C 0
ROSDR
P (0-30)
18-19
Edit
Stat
1-3
ROSDR
i-3
Mover Input
Left
20-27
General
Purpose Stats
4-5
ROSDR
4-5
Mo~er
Input Right
28
l Sign
6-11
ROSDR
6-11 Q and P Address Field
29 R Sign
12-15
ROSOR
12-15 Address Extension Field
30 Carry
16-i8
ROSDR
16-18 Ad,t,..., Control Field
31
RTL
19 Unused
0080
0-6
LSAR
20-24
ROSDR
19-25 Adder Latch
to
Ingole
7-8
LS
Function Register
25
Emulator Feature
9-13
J Register
26-28
ROSDR
25-27
LS
Addressing
14-18
MO
Counter
29-31
ROSDR
28-30
19
Unused
0090
0
ROSDR
P
~31-55)
20-25
Length Counter I (S,
P,
0-3)
l-3
ROSDR
32-34
Invalid Digit Test and
IC
Control
26-31 Length Counter 2 (S,
P,
0-3)
4-8
ROSDR
35-39
Gating
Into Add.r Latch
0084
0-3
LCS
Feature
9-12
ROSDR
40-43
Mover Destination
4
UnuMtd
13-14
ROSDR
44-45
Byte
Ctr
Function Control
i5-17
ROSDR
46-48 Counter Controls, MD, L Byte, M
Byte
18-20
ROSOi-
49-51 Cony Insert Control
5-8
LCS
Feature
9-31 Unused
0088
0-31 H Register
21-22
ROSDR
52-53 Mover Output Left
OOBC
0-23
Unused
23-24
ROSDR
54-55
Mover
Output
Right
24-27 H Register Fold (28-31)
25
Unused
28-31 Unused
26-28
Mover Function (CPU)
ooco
0-31 M Register
29-31
Mover Function (1/0)
0094 0
ROSDR
P (56-88)
00(4
0-23
Unused
24-27 M Regist°' Fold (28-31)
i-4
ROSCiR
57-60
Emit
Field
5-7
.
ROSDR
61-63 Outgotes to
Left
Adder Input
Gote
28-31
Unused
ooce
0-31
R Register
8
ROSDR
64
TC
Goting to Left
9-11
ROSDR
65-67 Outgotes to Right Adder Input
Gate
oocc
o-23
Unused
24-27
R Register Fold (28-31)
12-15
ROSDR
68-71 Adder Function
CPU
28-31 Unused
16-21
ROSDR
72-"'n Condition Branch
Grp
A
0000
0-31 L Register
22-26
ROSDR
78-82 Condition
Bronch
Grp 8
0004
0-23
Unused
27
ROSDR
83 Emulotor Feature
24-27 L Register Fold (28-31)
28-31
ROSO~
84-87
Stat
Setting Function
0098
0-4
Unused
28-31 Unused
0008
0-31
SOR
5
Emulator Feature
OODC
0-23
Unused
6-17
Previous
ROS
Addren
24-27
SOR
Fold (28-31)
18-23
Unused
28-31 Unused
24-25
ROSDR
88-89
Stat Setting Function
OOEO
0-3
1/0 Inst
(Start,
Test,
Holt,
Test)
26-31
RO
SOR
90-95
Emu
lotor Feature
4-6
Channel Number
009C
0
One
Syllable
Op
Stot
i
Refetch
Stat
7-10
Inst
Reply
11
Reply
2-4
Unused
12
Branch
on
Channel Interrupt
5
Emulator Feature
13
Proceed on Interrupt
6-17
Current
ROS
Address
14
Time
Out
18-23 Interrupt Register
24-31
PSW
32-39
15
Time
Out
Ck
16
Foul
OOAO
0-3
Half-Sum Cks
17-31 Unused
4-7
Sum
Cks
OOE4
0
Routine Received
8
Cony
Cks
9-11
L,
M,
MD
Ctr
Cks
12-13
GI
ond
G2
Ck
I
PCI
Enoble
2
Break-In
3
1/0
Routine
14-16
Mover
Cks,
U,
V,
W
4
Early First
Cycle
i7
Unused
5
First
Cycle
18-20
SAR
Cks
6
Chain
First
Cycle
FIGURE
12.
SCAN-OUT/LOGOUT,
LOCATIONS AND
DATA
(PART
2 OF 4)
24 (3/71) Model
50
FEMM

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IBM System/360 2050 and is the answer not in the manual?

IBM System/360 2050 Specifications

General IconGeneral
BrandIBM
ModelSystem/360 2050
CategoryComputer Hardware
LanguageEnglish

Related product manuals