EasyManua.ls Logo

IBM System/360 2050 - Page 26

IBM System/360 2050
198 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Channel
Channel
Only
Full
Only
Full
logout
Logout
Bih
Data
logout
logout
Bits
Data
OOE4
7
LS
Read
98
0108
17-20
Read (Bkwd,
Op,
Rdy,
Interface)
8
LS
Write
21-23
Write
(Op,
Rdy,
Interface)
9
Channel
to Adder
latches
Dato
Transfer and Control
24-31
Channel
Checks (Sim,
Ill,
Prag,
Stor
Prot,
Chan
Data,
10 Adder
latches
to Channel Dato Transfer and Control
11
Chain
9(
Chan
Ctr!,
IF
Ctrl,
Chain
l)
OIOC
0-27
Unused
12
Lost
Cycle
13
Break-Out
28-31
Group
3 Parity (Byte
Ctr,
lost
Word 2, Reg Full
B,
CD=
PC
Type)
14-17
Storage Byte Control RPgistcr
18
Unused
AO
0110
0-27
Unused
28-31
Group
4
parity
(UA
Fetch,
Cycle
Ctr Stop
0,
19-22
ROSDR
sa.
33, 34,
47'
48
Pritirity
l,
Stat
0)
23
First
Cycle
Check
24-31
Unused
A4
0114
0-7
Position Register (CCW-1 Type,
CCW-2
Type, Unit
Sel,
Rd
Store,
Wr
Fetch,
Encl
Up, Comport:, Interrupt)
OOE8
0-3
Buffer 1
B-10
Cycle
Ctr
Phase A Step
(I,
2,
3)
4-7
Buffer 2
11-13
Clock
(AO,
Al,
Step)
8-11 Buffer 3
14
local
Store Request
12-16
1/0 Stats
15
PCI
Request
17
Unused
I 16-17
Priority (2, 3)
18
I
1/0
Check Mode
IB-23 Request Register
(0-5)
19-21
Logs
(I,
2,
3)
22
Gate
Status
24-26
Stats
1-3
28-31
Common Channel
Detect
(LS,
PRI
l,
PRI
2-3, PCI,
23
log
Reset
24-31 Unused
Inhibit Routine)
AB
0118
0-6
General
Purpose Register
(l
-7)
OOEC
0-8
Bc·ff« I (P,
0-7)
7-8
Unused
9-17
Buffer 2 (P,
0-7)
9-13
Flag Register (CDA,
CC,
SILi, Skip, PCI)
18-31
I
Request
Log-Out
OOFO
0
Select
Out
I
Select
In
2
Op
In
14 Finish
15
First Word
16
First Byte
17 Total Record Fetch
3
Suppress
Out
IB
Write
Chain
Proceed
4
P.equest
In
19 Stop
Re
lease
5
Service
Out
20-22
Unu~d
6 Address
Out
23
Status
Next
latch
7 Command
Out
24-27
Multi-Purpose
(Cl-C4)
8
Ser.tice
In
28 Suppress
Out
9
Address
In
29 Request
In
10
Status
In
30
Servic2
Out
Hold
'
11-19
B~s
Out
(P,
0-7)
'
I
20
~rogr'am
Check. '
I
21
Storage
Prctect
Check
22-31
Unu11ed
~I
Block1
Status
In
'
AC
01
IC 0
Inhibit Read
Store,
'
1-4
A
Clock
(A,
B,
C,
0)
5 6
S~c!ol
P~rposc
!D
! , 02}
OOF4
0-3
Controlled
Emit
7
Instruction Scan
4-B
Routine Request Triggers {A, E 1-E4)
B
Poll
9-11
Priority (2,
3,
PCI)
12-17
Control Triggers
(CC,
OTC, UCW,
IB
Full,
Poll,
Burst Mode)
9 Poll Interrupt End
10
Instruction Inhibit
18-21
Mpx
1/0 Stats
22
Doto Transfer Control
II
BC
Ready
12
UA
to
Bus
Out
23
CC Reset Control
13
Select
Address
Out
24-31 Unused
14-15
Compare
(=
or I )
B8
OOFB
0-31
SE"lector
Channel
B Register
(0-3
I)
16
Interface
Chain
Data
Address
Fint
Byte
BC
OOFC
0-27
Unused
17
Chain
Oata
28-31
Selec.tor Channel 8 Register Parity
IB
Byte
Ctr
Mod Enoble
90
0100
0-27
Unused
19 Write
Chain
Ready
28-31
Selector
Chnnnel C
Re
rister Purity
20 Record
End
94
0104
0-31
Selector
Channel C Register
(0-31)
21
Op
In
Test
98
0108
0-1
Byte
Counter
A (2, I)
2-4
Byte
CounterB(P,
2,
I)
5-6
End Register (2,
I)
22
Channel
Stop
23
Select
Out
24 Sel
In
7-8
Last Words (3,
I)
25
Op
In
9
EOR
Count Interlock
26-2B
Service
Out,
Address
Out,
Command
Out
10
EOR
I Latch
29-31
Service
In,
Address In, Status
In
II
EOR
2 Latch
BO
0120
0-27
Unused
12
EOR
Read Interlock
28 Position Register Transfer
13
B Almost Changed
29
Channel
In
Use
I
14
lOcol Store
fnoble
15
local
Store Register Full
16
C Register Full
30
Stop
31
Stop Routine
0124
0-15
Rewrved for
Selector
Channel
and Misc
Features
16-31 Reserved for Mpx
Channel
FIGURE
12.
SCAN-OUT/LOGOUT:
LOCATIONS AND
DATA
(PART
3
OF
4)
Maintenance
Featurea
(3/'11)
25

Table of Contents

Related product manuals