Contaminate Requirement
Notes:
1. ANSI/ISA-S71.04. 1985. Environmental conditions for process measurement and control systems: Airborne contaminants, Instrument Society of America,
Research Triangle Park, NC, 1985.
2. The derivation of the equivalence between the rate of copper corrosion product thickness growth in Å/month and the rate of weight gain assumes that Cu
2
S and
Cu
2
O grow in equal proportions.
3. The derivation of the equivalence between the rate of silver corrosion product thickness growth in Å/month and the rate of weight gain assumes that Ag
2
S is the
only corrosion product.
4. The deliquescent relative humidity of particulate contamination is the relative humidity at which the dust absorbs enough water to become wet and promote ionic
conduction.
5. Surface debris is randomly collected from 10 areas of the data center on a 1.5 cm (0.6 inch) diameter disk of sticky electrically conductive tape on a metal stub. If
examination of the sticky tape in a scanning electron microscope reveals no zinc whiskers, the data center is considered free of zinc whiskers.
Specifications
Edit online
Specifications for the tape drive.
Specifications for tape cartridges are given in Environmental and shipping specifications for tape cartridges.
Table 1. Specifications
Physical Specifications
Specification Dimensions
Width 213 mm (8.4 in.)
Length 332 mm (13.1 in.)
Height 58 mm (2.3 in.)
Weight 4.3 kg (9.4 lbs.)
Power Specifications
AC line voltage 100 - 240 Vac
Line frequency 50 - 60 Hz, auto-ranging
Line current at 100 Vac 0.48 A
Line current at 240 Vac 0.20 A
Other Specifications
Maximum altitude 3048 m (10,000 ft)
Maximum altitude for shipping 12192 m (40,000 ft)
Environmental Specifications
Environmental Factor Operating Storage Shipping
Temperature 10 - 38°C (50 - 100°F) -40 to 60°C (-40 to 140°F) -40 to 60°C (-40 to 140°F)
Relative humidity 20 - 80% 10 - 90% 10 - 90%
Maximum wet bulb temperature 26°C (79°F) Non-condensing Non-condensing
Installing
Edit online
This is a customer setup unit. It is the customer's responsibility to install this product.
Installation involves the following steps.
Avoiding drive damage
To avoid static electricity damage when the drive is handled, use the following precautions.
Unpacking the drive
Unpack the drive and store the packaging for future moves or shipping.
Verifying the shipment
Ensure that the following items are included in the shipment.
Installing the rack mount kit (optional)
If you need to install a rack mount kit, follow these procedures.
Inspecting the power cord and outlet
Inspect the power cord and receptacle, and check that the outlets are properly grounded.
Positioning the tape drive
Position the unit so it is convenient to the server.
Installing the SAS host adapter card (if required)
If no other devices are attached to your server, a SAS host adapter might need to be installed in the server.
Connecting the SAS interface cable
Each tape drive is required to have a dedicated bus to the initiator, referred to as point-to-point connection. SAS architecture does not support multiple tape drives
connected to a single host adapter port. The maximum SAS cable length that can be used to connect the host adapter to the tape drive varies depending on the
type of SAS connection. See Optional features for the maximum cable length that can be used.
Connecting power
Steps to install and connect a power cable to your unit.
IBM TS22xx - TS2290, TS2280, and TS2270 9