v  PCI  slots  2  through  5  support  full-length  3.3  V  signaling  adapters  only. 
v  The  PCI  configuration: 
–  Slot  1  is  a  PCI  Express  x8  slot  with  x4  links,  PCI  Express  1.0a  compliant. 
–  Slot  2  and  3  are  PCI  Express  x8  slots  with  x8  links,  PCI  Express  1.0a 
compliant. 
–  Slots  4  and  5  are  PCI-X  133/64  slots,  PCI-X  2.0  compliant. 
–  Slot  6  is  a  PCI  33/32  slot,  PCI  2.2  compliant.
Note:
  The  ServeRAID-8k  and  ServeRAID-8s  SAS  Controllers  override  the 
standard  functionality  of  the  integrated  SAS/SATA  controller  with  RAID 
capabilities. 
v  The  system  scans  PCI  slots  1  through  6  to  assign  system  resources.  The  system 
then  starts  (boots)  the  system  devices  in  the  following  order,  if  you  have  not 
changed  the  default  boot  precedence:  integrated  Ethernet  controller, 
ServeRAID-8k  SAS  Controller,  and  then  PCI,  PCI-X,  and  PCI  Express  slots. 
Note:  To  change  the  boot  precedence  for  PCI  and  PCI-X  devices,  start  the 
Configuration/Setup  Utility  program  and  select  Start  Options  from  the  main 
menu.  See  the  “Using  the  Configuration/Setup  Utility  program”  on  page  50  for 
details  about  using  the  Configuration/Setup  Utility  program. 
v  The  server  uses  a  rotational  interrupt  technique  to  configure  PCI  adapters  so  that 
you  can  install  PCI  adapters  that  do  not  support  sharing  of  PCI  interrupts. 
Attention:  Static  electricity  that  is  released  to  internal  server  components  when 
the  server  is  powered-on  might  cause  the  server  to  stop,  which  might  result  in  the 
loss  of  data.  To   avoid  this  potential  problem,  always  use  an  electrostatic-discharge 
wrist  strap  or  other  grounding  system  when  working  inside  the  server  with  the 
power  on. 
To  install  an  adapter,  complete  the  following  steps: 
1.  Read  the  safety  information  that  begins  on  page  v  and  “Installation  guidelines” 
on  page  21. 
2.  Turn  off  the  server  and  peripheral  devices,  and  disconnect  the  power  cords  and 
all  external  cables.  Remove  the  left-side  cover. 
3.  See  the  documentation  that  comes  with  the  adapter  for  any  cabling  instructions 
and  information  about  jumper  or  switch  settings.  (It  might  be  easier  for  you  to 
route  cables  before  you  install  the  adapter.) 
4.  Open  the  front  and  rear  adapter  retention  clips. 
5.  Remove  the  expansion-slot  cover. 
 
Chapter  2.  Installing  optional  devices  25