DX8
Dual Balance Charger/Discharger/DC Power
- 19 -
1. For example, a 12V/60W bulb as the load of To Channel, it should set Voltage Limit =12VCurrent Limit=60/12=5A.
2. When the battery as the load of To Channel, Voltage Limit and Current Limit are not settablesee details on Channel
Regenerative Mode .
LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Discharge Advanced Setup
Click "Advanced" to enter DISCHARGE ADVANCED SETUP interface.
1. Tick Extra Discharge Enable to activate discharge enable, see more details on Lithium Battery Extra Discharge
Mode.
2. Tick Balance Enable to activate balance discharge; when discharge enters the CV phase, it starts to balance the cell
voltages.
LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Discharge Safety Setup
Click "Safety" to enter DISCHARGE SAFETY SETUP interface.
LiPo/LiIo/LiFe/LiHV/LTO/NiZn/User Cycle Setup
Select ProgramCycle to enter CYCLE SETUP interface.
LiPo/LiIo/LiFe/LiHV/LTO/User Only Balance Feature
Select ProgramBalance Only to enter Balance Only setup interface.
Channel Join: Resistance or bulbs (default)
Charging battery
Voltage Limit: 0.1V-40V; default: 12V
Current Limit: 0.05A-30A; default: 1A
Cut-Temp: 20-80℃; default: 45℃
Max Capacity: 50%-200%; default: 90%
Safety Timer: 1Min-9999Min; default: off
Cycle Mode: CHG
DCHG(default),DCHG
CHG
CHG
DCHG CHG, DCHG
CHG DCHG,
CHG
DCHG STO, DCHG
CHG STO
Cycle Count: 1-99; default: 3
Delay Time: 0Min-9999Min; default: 3Min