CONNECTING THE PS-125 / PS-85 DC POWER SUPPLY
PS-125 / PS-85
Connect to an AC outlet
using the supplied AC cable.
DC power cable
DC power
socket
CONNECTING A NON-ICOM
DC POWER SUPPLY (For Europe versions)
Transceiver
DC power
socket
To non-Icom
power supply
[GND]
OPC-639
CONNECTING A NON-ICOM
DC POWER SUPPLY
Transceiver
DC power
socket
To AC outlet
Supplied
DC power cable
13.8 V
Black
30 A fuses
Red
20 A
13
2
INSTALLATION AND CONNECTIONS
Power supply connections
Use the optional PS-125 / PS-85 DC POWER SUPPLY
when operating the IC-706MKIIG with AC power.
Refer to the diagram below for connection.
CAUTION: Before connecting the DC power
cable, check the following important items. Make
sure:
The [POWER] switch is OFF.
Output voltage of the power source is 1215 V
when you use a non-Icom power supply.
DC power cable polarity is correct.
Red : positive (+) terminal
Black : negative () terminal
Grommet
CONNECTING A VEHICLE BATTERY
NEVER
connect to
a 24 V battery.
Note: Use terminals for
the cable connections.
Crimp
Solder
Supplied
DC power cable
red
black
12 V
battery
Note: When using the PS-125, the IC-
706MKIIG Europe version complies with
EMC directives even if the OPC-639 is
not used.

Table of Contents