EasyManua.ls Logo

Icom IC-7800

Icom IC-7800
555 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4 - 2
4-2 OSC UNIT ADJUSTMENTS
REFERENCE
OUTPUT
REF IN
OUTPUT
REF OUT
OUTPUT
ADJUSTMENT
ADJUSTMENT ADJUSTMENT CONDITION
MEASUREMENT
VALUE
POINT
UNIT LOCATION UNIT ADJUST
1
2
3
Set the OSC unit to the external ref-
erence mode on the set mode.
MAIN display frequency
: 10.000 MHz
Connect an SSG to J71 on the
OSC unit and set as;
Frequency : 10.000 MHz
Level :
71 mV* (10 dBm)
Modulation : OFF
Terminates J73 with 50 .
Receiving
Receiving
Terminates J72 with 50 .
Receiving
Set the OSC unit to the internal ref-
erence mode on the set mode.
Receiving
Terminates J73 with 50 .
Receiving
Terminates J72 with 50 .
Receiving
OSC
OSC
OSC
Connect an RF volt-
meter to J72.
Connect an RF volt-
meter to J72.
Connect an RF volt-
meter to J73.
Connect an RF volt-
meter to J71.
Connect an RF volt-
meter to J72.
Connect an RF volt-
meter to J73.
Maximum voltage
0 dBm ±3.0 dB
0 dBm ±3.0 dB
10.0 dBm ±3.0 dB
0 dBm ±3.0 dB
0 dBm ±3.0 dB
OSC
Adjust
repeatedly
L61,
L62
Verify
Verify
Verify
Verify
Verify
*This output level of a standard signal generator (SSG) is indicated as SSGs open circuit.