4 - 16
4-5 PA200W BOARD ADJUSTMENTS
IDLING
CURRENT
(For driver)
(For final
amplifier)
ADJUSTMENT
ADJUSTMENT ADJUSTMENT CONDITION
MEASUREMENT
VALUE
POINT
UNIT LOCATION UNIT ADJUST
1
2
3
• Preset R301, R407 and R410 on
the PA200W unit to max. CCW.*
• [MIC] gain : max. CCW*
• Main display frequency
: 14.100 MHz
• Mode : USB
• Apply no audio signals to [MIC]
connector.
• Transmitting
PA200W
Connect a DC amme-
ter between W1 and
EP501.
1.0 A higher from the
previous value of the
adjustment.
1.0 A higher from the
previous value of the
adjustment.
1.0 A higher from the
previous value of the
adjustment.
PA200W
R301
R407,
R425
R410,
R426
*CCW: Counter clockwise