TM 10-7360-226-13&P
CONTAINERIZED KITCHEN (CK) 0016 00
PREVENTIVE MAINTENANCE CHECKS AND SERVICES
0016 00-4
Table 1. Before Operation PMCS for CK - Continued
ITEM
NO.
INTERVAL MAN-
HOUR
ITEM TO BE
CHECKED OR
SERVICED
PROCEDURE EQUIPMENT
NOT READY/
AVAILABLE IF:
Inspect ratchet straps for fraying, cuts,
damaged ratchet. Inspect rubber
straps for cuts, missing or damaged
hooks
Damaged straps
or ratchets,
hooks missing or
damaged
2 Before Mechanical
room
Inspect intake and exhaust fans for
damage, loose or missing parts.
Missing or
damaged
hardware.
Inspect awning assembly for damage.
Inspect cloth exhaust ducts for
damage, proper installation.
3 Before Cook center Inspect base assembly for damage,
weld cracks.
Inspect fuel line assembly for leaks,
damage.
Any fuel leak.
Inspect 24 VDC power cable assembly
for frayed wires, damaged connectors.
Frayed wire or
damaged
connector.
Inspect ventilation hood assembly for
loose, missing or damaged hardware.
Check fans for proper operation.
Fans inoperable.
Inspect grease filters and filter frame
for loose, missing or damaged
hardware or cracked welds. Check for
grease accumulation. Clean filters as
necessary.
Inspect griddle, steam table, cook pot
cradles and adapters, base rack,
burner rack for cracks and damage.
Damage, cracked
weld.
4 Before ECU filters Inspect filters for damage, cleanliness.
Remove and clean as necessary
5 Before Dual oven
assembly
Inspect ovens and base cabinet for
damage, weld cracks, missing parts.
Inspect fuel line assembly for leaks,
damage.
Any fuel leak.
Inspect 24 VDC power cable assembly
for frayed wires, damaged connectors.
Frayed wire or
damaged
connector.