TM 10-7360-226-13&P
CONTAINERIZED KITCHEN (CK) 0026 00
UNIT MAINTENANCE PROCEDURES
0026 00-4
Figure 2. Appliance Control Box.
1 Input Power 2 Intake/Exhaust Fan
3 Input Power 4 Intake/Exhaust Fan
5 Input Power 6 Heater
7 Refrigerator 1 8 Heater
9 Refrigerator 2 10 Heater
11 MBU Converter 12 Convenience Outlets
13 ECU 14 Mechanical Room Outlet
15 ECU 16 Warming Cabinet
17 ECU 18 ECU Control Box
19 Lights 20 Blank/not used
21 Blank/not used 22 Blank/not used
23 Blank/not used 24 Appliance Control Box
Figure 3. Circuit Breaker Layout of the Power Distribution Panel.
WATER PUMP:
CIRCUIT BREAKER
SWITCH
WATER HEATER:
CIRCUIT BREAKER
SWITCH
OVEN FAN:
CIRCUIT BREAKER
SWITCH
HEATER FAN:
CIRCUIT BREAKER
SWITCH
CABLE
ENTRANCE