TM 10-7360-226-13&P
CONTAINERIZED KITCHEN (CK) 0005 00
DESCRIPTION OF OPERATOR CONTROLS AND INDICATORS
0005 00-6
POWER CONVERTER
ON
OFF
POWER
90-132V AC
47-63 Hz
OUTPUT
A
OUTPUT
B
26 V DC
600W
Continuous
1
2
3
4
POWER CORD
Figure 5. MBU Converter.
MBU Control Panel
Each MBU has an integral control panel, Figure 6. The MBU controls and indicators are listed
below. Refer to TM 10-7310-281-13&P for more information about the MBUs.
START pushbutton (1): Starts the burner.
STOP pushbutton (2): Shuts down the burner.
FUEL pushbutton (3): Starts the fueling function.
POWER pushbutton (4): Turns the main power on and off.
FIRING RATE control (5): Adjusts the burner firing rate.
RUN indicator (6): Lights when the burner is operating.
WARM UP indicator (7): Lights when the burner is warming up.
FUELING/FUEL indicator (8): Lights when the tank is filling (during fueling) or full.
LOW FUEL indicator (9): Lights when there is about 30 minutes of fuel remaining.
VOLTAGE indicator (10): Lights when voltage from the power converter is incorrect.
SERVICE indicator (11): Lights to indicate a malfunction.
TOTAL HOURS indicator (12): Shows accumulated hours of operation. Displays
error codes when malfunctions occur. Background light indicates power-on condition.