N Squelch attenuator
The transceiver has an RF attenuator related to the squelch
level setting. Approx. 10 dB attenuation is obtained at maxi-
mum setting.
The squelch attenuator allows you to set the minimum signal
level needed to open the squelch. The attenuator function can
be deactivated in set mode.
± Rotate [SQL] clockwise past the 13 o’clock position to ac-
tivate the squelch attenuator.
Attenuation level can be adjusted up to 10 dB (approx.) between
13 o’clock and fully clockwise position.
Squelch is
open.
Squelch
attenuator
Squelch
threshold
Shallow Deep
Noise squelch
NOTE: The squelch attenuator functions even when the
monitor function is in use. Thus it is recommended to set
the [SQL] control between the 10 and 13 o'clock positions
when using the monitor function.
D Squelch attenuator setting
q
Enter “AT-ATT” in FUNC set mode (SET).
MENU SET FUNC AT-ATT
(p. 63)
(Push [MENU ]), (Rotate [DIAL], then push [ ](MONI).)
[DIAL]
[MENU ]
[ ]
w Rotate [DIAL] to turn the squelch attenuator function ON
and OFF.
• Select “OFF” to deactivate the squelch attenuator function.
e Push [MENU ] to exit the set mode.