6-3 FREQUENCY VERIFICATION
The output level of the signal source is measured at the load end (PD).
ADJUSTMENT ITEM NAME
REPEATER’S
CONDITION
OPER ATION VALUE
REFERENCE
FREQUENCY
-Adjustment (Auto)-
1 [REF OSC1] Receiving Connect the 10 MHz reference frequency
source to the [REF IN 10 MHz] connector,
and set it to:
Frequency: 10.000000 MHz
Level
 
Modulation: None
Push the PC's [ENTER] key.
OK is displayed
in the Result row.
6-4 RECEIVE VERIFICATIONS
The output level of the standard signal generator (SSG) is measured at the load end (PD).
6-5 RESTARTING THE REPEATER
1) Click [Stop],then perform the All Reset on the ID-RP3 ADJ window.
 Turn OFF the repeater.
ADJUSTMENT ITEM NAME
REPEATER’S
CONDITION
OPER ATION VALUE
RECEIVE
SENSITIVITY
-Adjustment (Auto)-
1 [Total Gain VHF
PRE ON ref]
Receiving Connect the SSG to the [RX ANT]
connector, and set it to:
 
Level
 
Modulation: None
Push the PC's [ENTER] key.
OK is displayed
in
the Result row.
[Total Gain VHF
PRE ON set]
Set the SSG output as:
Level
: OFF
Push the PC's [ENTER] key.
3 [VHF AGC set] Set the SSG output as:
Level
 
Push the PC's [ENTER] key.