6-1
SECTION 6 ADJUSTMENT PROCEDURE
STANDARD SIGNAL
GENERATOR
RF POWER METER
Supplied DC power cable
25 A fuses
To [RX ANT]
To [USB]
To [DC13.8V]
To [SERVICE]
[GND]
PLUG INFORMATION
[MIC]
To [TX ANT]
<Rear view>
Supplied USB cable
PC
_ +
DC POWER SUPPLY
10 MHz
REFERENCE FREQUENCY
SIGNAL SOURCE
+
AC MILLIVOLTMETER
AUDIO GENERATOR
+
+
6-1 PREPARATION
■ REQUIRED EQUIPMENT
EQUIPMENT GRADE AND RANGE EQUIPMENT GRADE AND RANGE
Adjustment software ID-RP3 ADJ Programming cable USB cable ( Supplied with the repeater)
DC power supply
Output voltage: 13.8 V
Current capacity: 10 A or more
Standard signal
generator (SSG)
Frequency range: 0.1 ~ 300 MHz
RF power meter
Measuring range: 0.1 ~ 30 W
Frequency range: 100 ~ 300 MHz
10 MHz reference
frequency signal
source
Frequency: 10.000000 MHz
Accuracy: ±5×10
-4
ppm or less
Audio generator (AG)
Frequency range: 300 ~ 3000 Hz
Output level: 1 ~ 500 mV
AC millivoltmeter Measuring range: 1 mV ~ 10 V
■ SAVE THE PROGRAMMING DATA
• Adjusting the repeater will change the programming setting.
• Before adjusting, save the programming data of the repeater with the programming software.
After adjusting, write back the programming data.
■ CONNECTIONS