38
10
SERVICE MAN MENU
■ SPD adjustment
q Push [MENU]/[ ], [q] and [u] one or more times
to display the “SERVICE MAN” menu.
w Hold down [q] until the “SPD ADJ.” section be-
comes highlighted.
e Push [t] or [u] to enter the pulse rate of the speed
sensor unit (pulse numbers per one nautical mile).
r Push [MENU]/[ ] to return to the normal screen.
■ RANGE selection
SERVICE MAN
SPD ADJ.
HDG ADJ. 0.0
˚
HV
SETUP MEMORY
24000 MONITOR
HEATER
5731.0H
TX TIME
30.0
OUTPUT
ENGLISH
VOLTAGE
MG
340
75
3.0
0.55
TIMING ADJ.
1/8 3/4 2 6
1/4 1 3 8
1/2 1.5 4 12
16
24
32
36
48
RANGE
*
1
⁄
4
NM range will be skipped.
72
64
q Push [MENU]/[ ], [q] and [u] to display the
“SERVICE MAN” menu.
w Hold down [q] until the “RANGE” section becomes
highlighted.
e Push [p] or [q] to choose the selectable screen
ranges with [+]/[ ] or [–]/[ ] on the dis-
play.
r Push [t] to skip from the range selection, or push
[u] to cancel skipping.
t Push [MENU]/[ ] to return to the normal screen.
Selectable ranges:
1
⁄8,
1
⁄4,
1
⁄2,
3
⁄4, 1, 1.5, 2, 3, 4, 6, 8, 12,
16, 24, 32, 36, 48*, 64
†
, 72
†
(NM)
*48 NM range is available for the MR-1200TII/TIII.
†
64 and 72 NM ranges are available for the MR-1200TIII only.