20.10
Using soapy water on both sides,
perform a crankcase leak down test
using pressure gauge and vacuum gauge.
20.12
Crankcase separation.
The universal puller and grip plate are
required to separate the crankcase.
20.11
Use pressure gauge to perform a leak
down test. Pressure should hold at 7 psi
(0.5 bar).
20. CRANKCASE