Payout Mode Error
»
Code: E12
LED Light Indicator: Red light
LCM Display: As shown in figure below
Cause: Signal from payout module was not
received when power was turned on.
Corrective Method: Ensure that the signal wire
is connected to the payout module.
«
Communication Error
»
Code: E13
LED Light Display: 1 red
LCM Display: As shown in figure
Cause:
1. Two seconds after activation, the SYSTEM did not wait for the READY signal from
the DEVICE and jumped to the exception mode.
2. Two seconds after a transaction, the SYSTEM did not wait for the READY signal
triggered by the DEVICE.
Corrective Measure:
1. Ensure that the machine interface and the VMC
interface are consistent.
2. Ensure that the interface transmission wire is
properly connected.
Payout Module Error
E12
No Communication
with VMC E13