PRODUCT SPECIFICATIONS
Operating Voltage: 10VDC to 60VDC
System Current Rating: 60A (Continuous)
Fuse Capacity: 15A GMT Fuse x 6
Continuous Load Rating: 12A per output
CAUTION: Ensure that the load total connected to the fused outputs does
not exceed the system current rating.
NOTE: Most fuses should be continuously operated at no more than
80% of their nominal current rating.
Consult the fuse manufacturers specifications.
Power Consumption: 4 W (all outputs enabled)
Alarm Form-C Contacts: Form “C” Dry Contacts
1A/60VDC Max
Alarm Sensor Inputs: Four external dry contact alarm inputs,
configurable for NC or NO contacts. Applied
voltage 3.3V, 0.4mA for contact closure
detection
Ethernet: 10Base-T/100Base-T, RJ45 Connector
SNMP: SNMP v1/v2c/v3 supported
Network Security: Password protection, SSL encryption for HTTPS ,
SMTP (TLS 1.2) and SNMPv3 protocols
Operating Temperature: -20°C to +60°C
Weight: 2.7lbs (1.22kg)