* All installations in England and Wales must be to Local Authority Building Control (LABC) either directly or through a
Competent Persons Scheme. A Building Regulations Compliance
will then be issued to the customer.
© Heating and Hotwater Industry Council (HHIC) www.centralheating.co.uk
It is recommended that your heating system is serviced regularly and that the appropriate Service Interval Record is completed.
Service Provider
SERVICE RECORD
SERVICE 01
AND
²
%
(Where Possible) AND
²
%
Signature
SERVICE 02
AND
²
%
(Where Possible) AND
²
%
Signature
SERVICE 03
AND
²
%
(Where Possible) AND
²
%
Signature
SERVICE 04
AND
²
%
(Where Possible) AND
²
%
Signature
SERVICE 05
AND
²
%
(Where Possible) AND
²
%
Signature
SERVICE 06
AND
²
%
(Where Possible) AND
²
%
Signature
SERVICE 07
AND
²
%
(Where Possible) AND
²
%
Signature
SERVICE 08
AND
²
%
(Where Possible) AND
²
%
Signature
SERVICE 09
AND
²
%
(Where Possible) AND
²
%
Signature
SERVICE 10
AND
²
%
(Where Possible) AND
²
%
Signature

Table of Contents

Other manuals for IDEAL LOGIC COMBI ESP1 30

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDEAL LOGIC COMBI ESP1 30 and is the answer not in the manual?

IDEAL LOGIC COMBI ESP1 30 Specifications

General IconGeneral
ModelLogic Combi ESP1 30
CategoryBoiler
Boiler TypeCombi
MountingWall Mounted
Fuel TypeGas
Output30 kW
Domestic Hot Water Output30 kW
Efficiency94%
ErP Heating Efficiency ClassA
ErP Water Heating Efficiency ClassA
DHW Flow Rate12.4 l/min
Central Heating Flow Temperature Range30-80°C
Dimensions700 x 395 x 278 mm
Warranty7 years

Related product manuals