MiniPad rPad User Guide
16
© 2015-2017 Identix Inc. All Rights Reserved.
Behavior of Search Mode and Sessions on intermittent reading field
Inventory Gen2 Session
Session= X set the session under Gen2 standard for Tag inventory. Chose session: 0, 1, 2 or
3.
Tag Population Estimate
TagPopulationEstimate= 4 an estimate of the tag population in view of the RF field of the
antenna
Defines the estimation of the tag population you want to read
This parameter is used to optimize the anti-collision algorithm
Set this value to a power of 2
Inventory Cycle
InventoryCycle=0,0 sets the inventory cycle duration and interval (on-off) in milliseconds. Set
to 0,0 (default) for continuous inventory
Users can define the inventory cycle (on/off) interval. For instance, to read tags for a period