If a follower zone is violated without a prior entry/exit zone violation, it will be treated as an
instant zone. If an instant zone is violated during this period, an alarm condition will immediately be
registered. Select the appropriate value for the primary entry delay from the same table for sub-location 6.
Sub-location 8 Secondary Entry Delay
(Values identical to Sub-location 6) The secondary entry delay applies to secondary entry/exit zones.
Once an entry has been initiated, subsequent violations of any entry zone will NOT reset the entry time.
Use the same table from Sub-location 6 to look up the value for the time interval required.
Sub-location 9 Auto Arm Time (Default = disabled)
This sub-location stores the time at which a particular partition will auto arm. The data format entered into
this location is “hhmm” based on a 24 hour clock. Example: To auto arm at 11:35pm, enter 2335. All four
digits must be entered, include any leading zeros (0100 for 1 am).
To disable this feature, ensure that no day of the week is selected in Sub-location 10.
Sub-location 10 Auto Arm Days (Default = all OFF)
This Bitmapped sub-location sets the days on which the partition will auto arm at the time programmed in
sub-location 9.
LED 1 Monday
LED 2 Tuesday
LED 3 Wednesday
LED 4 Thursday
LED 5 Friday
LED 6 Saturday
LED 7 Sunday
All OFF (Auto Arm Disabled)
Sub- location 11 Auto Disarm Time
This sub-location stores the time that the partition will auto disarm. The format of data entered into this
location is “hhmm” based on a 24 hour clock. For example: To auto-disarm at 11:35 am, enter 1135.
Sub-location 12 Auto Disarm Days
This Bitmapped sub-location sets the days on which the partition will auto-disarm at the time
programmed in sub-location 11.