IDS 1632 Installer Manual 700-256-02K Issued September 2009
50
NOTE:
Auto Disarm, if required, must be enabled per partition.
See sub-location 4.
Sub-location 13 Auto Arm Delay
This location selects the delay period for the keypad buzzer warning that is initiated before the panel auto
arms. At the completion of the Auto Arm Delay, the panel will arm. A valid user code entered during the
delay period will cancel the auto arming.
Value
Delay
Value
Delay
0
3 seconds
8 (Default)
2 minutes
1 10 seconds 9 3 minutes
2 15 seconds 10 4 minutes
3 20 seconds 11 5 minutes
4 25 seconds 12 10 minutes
5 30 seconds 13 15 minutes
6 45 seconds 14 18 minutes
7 1 minute 15 21 minutes
Sub-location 14 Keypads to Display this Partition’s Zones
Keypad ID
Keypad ID
1 Keypad 1 9 Keypad 9
2 Keypad 2 10 Keypad 10
3 Keypad 3 11 Keypad 11
4 Keypad 4 12 Keypad 12
5
Keypad 5
13
Keypad 13
6 Keypad 6 14 Keypad 14
7 Keypad 7 15 Keypad 15
8 Keypad 8 16 Keypad 16
Sub-location 15 Keypads to Access the Partition
Use the same table above to select the keypads that will have access to the current partition.
Partition Reporting Codes (for 4 x 2 & Domestic)
For all these locations, a two digit hexadecimal code must be programmed. To disable a reporting code
a double zero (00) must be entered into the corresponding location. Note that if one of the above
mentioned reporting digits is inadvertently omitted or programmed as a zero, the code will not be
reported. The exception to this rule is when using domestic reporting where only the first digit is used.
Sub-location 16 Duress Reporting Code
This code is reported when a duress code is entered.
Sub-location 17
Keypad Panic Reporting Code
This code is reported when the [P] key on a keypad is held down for two seconds.