Sub-location 18 Keypad Fire Reporting Code
This code is reported when the [F] key on the keypad is held down for two seconds.
Sub-location 19 Keypad Medical Reporting Code
This code is reported when the [M] key on the keypad is held down for two seconds.
Sub-location 20 Keypad Lockout Reporting Code
This code is reported when a keypad lockout condition occurs.
Sub-locations 21 – 44 Partition Programmable Outputs
See “System Programmable Outputs” for details on programming the programmable outputs. The table
below summarises the partition specific events that can be assigned to the outputs.
Summary of Partition Event Driven Programmable Outputs
Sub-Loc
Event
Output
Default Action
21 Close Programmable Output 3 Set High [0]
22 Stay Close Programmable Output Disabled
23 Open Programmable Output 3 Set Low [1]
24
Cancel Programmable Output
Disabled
25
Alarm Restoral Programmable Output
Disabled
26 Bypass Programmable Output Disabled
27 Forced Arm Programmable Output Disabled
28 Zone Tamper Programmable Output Disabled
29 Zone Tamper Restoral Programmable Output Disabled
30 Zone Shutdown Programmable Output Disabled
31 Zone Shutdown Restoral Programmable Output Disabled
32 Keypad Panic Programmable Output 1 Pulse High [2]
33 Keypad Fire Programmable Output Disabled
34 Keypad Medical Programmable Output Disabled
35
Keypad Lockout Programmable Output
Disabled
36
Duress Programmable Output
1
Pulse High [2]
37 Verifies Alarm Programmable Output Disabled
38 Burglary Programmable Output 2 Pulse High [2]
39 Panic Programmable Output 1 Pulse High [2]
40 Fire Programmable Output Disabled
41 Tamper Zone Programmable Output Disabled
42 Siren Programmable Output Disabled
43 Strobe Programmable Output Disabled
44 Chime Programmable Output Disabled