Page #65 background imageLoading...
Page #65 background image
IDS X Series Training V2.3 | Default 6
65
Location 571 Global Split Reporting 1
LED
Factory
Default
Default
6
Action
LED
On/Off
Reporting Pair
1
ON
OFF
Enable AC fail reporting
9
OFF
Telephone module 1
2
OFF
OFF
Disable communication fail reporting *
10
OFF
Telephone module 1
3
ON
OFF
Enable telephone line tamper reporting
11
OFF
Telephone module 1
4
ON
OFF
Enable siren fail reporting
12
OFF
Telephone module 1
5
ON
OFF
Enable panel low battery fail reporting
13
OFF
Telephone module 1
6
ON
OFF
Enable aux 12V fuse fail reporting
14
OFF
Telephone module 1
7
OFF
OFF
Installer Reset Required
15
OFF
Telephone module 1
8
ON
OFF
Enable box tamper reporting
16
OFF
Telephone module 1
Location 572 Global Split Reporting 2
LED
Factory
Default
Default
6
Action
LED
On/Off
Reporting Pair
1
ON
OFF
Enable bus-wired peripheral
tamper reporting
9
OFF
Telephone module 1
2
ON
OFF
Enable bus-wired peripheral fail
reporting
10
OFF
Telephone module 1
3
OFF
OFF
Disable bus-wired peripheral low
battery reporting *
11
OFF
Telephone module 1
4
ON
OFF
Wireless Detector Battery Low
12
OFF
Telephone module 1
5
OFF
OFF
Wireless Detector Supervision fail
13
OFF
Telephone module 1
6
OFF
OFF
Wireless Receiver Signal Jammed
14
OFF
Telephone module 1
7
OFF
OFF
Wireless Detector RSSI Low
15
OFF
Telephone module 1
8
ON
OFF
AC Restored
16
OFF
Telephone module 1
Location 573 Global Split Reporting 3
LED
Factory
Default
Default
6
Action
LED
On/Off
Reporting Pair
1
OFF
OFF
Comms Restored
9
OFF
Telephone module 1
2
OFF
OFF
Comms Tamper Restore
10
OFF
Telephone module 1
3
OFF
OFF
Siren Restore
11
OFF
Telephone module 1
4
OFF
OFF
Battery Restore
12
OFF
Telephone module 1
5
OFF
OFF
Aux 12V Restored
13
OFF
Telephone module 1
6
OFF
OFF
Installer Reset restored
14
OFF
Telephone module 1
7
ON
OFF
Box tamper restored
15
OFF
Telephone module 1
8
ON
OFF
Bus device tamper restored
16
OFF
Telephone module 1