EasyManuals Logo

IDS X16 User Manual

IDS X16
87 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #81 background imageLoading...
Page #81 background image
IDS X Series Training V2.3 | Standard Master User Functions
81
Option 23 - Button Properties
A button can be changed from the default settings by changing the properties.
Changing a button‟s property example:
Option 24 - Relay Properties
The following properties can be set:
Example:
Option 25 - Relay Pulse Time
The default pulse time is 1.5 seconds.
When entering the time, enter in the following format “mmss”.
Example:
Zone LED
Property
1
Relay 1
2
Relay 2
3
Arm / Disarm
4
Stay Arm
5
Panic
Instruction
Key presses
Press and hold the [*] key for 3 seconds
[*]
Enter the master code, followed by the [*] key
[1][2][3][4] [*]
Enter the value to change the button properties, followed by the [*] key
[2][3] [*]
Enter the remote receiver ID that the transmitter will be taught to, followed by the [*] key
[1] [*]
Enter the button number, followed by the [*] key
[2] [*]
Enter the property number, followed by the [*] key
[1] [*]
When complete press the [#] key
[#]
This will leave you in the remote receiver menu
Zone
LED
Property
Description
1
Secure
When power is lost the relay rests in the opposite position. I.e. Normally closed will rest in
normally open
2
Panic
When a panic is triggered via a button, or the 3 second hold option, the relay will trigger
3
Retrigger
This stops the relay from retriggering for 20 seconds after an initial trigger
4
Pulse
The relay will trigger and then reset without any intervention
Instruction
Key presses
Press and hold the [*] key for 3 seconds
[*]
Enter the master code, followed by the [*] key
[1][2][3][4] [*]
Enter the value to change the relay properties, followed by the [*] key
[2][4] [*]
Enter the remote receiver ID that the transmitter will be taught to, followed by the [*] key
[1] [*]
Enter the relay number, followed y the [*] key
[2] [*]
Enter the property number, followed by the [*] key
[2] [*]
When complete press the [#] key
[#]
This will leave you in the remote receiver menu
Instruction
Key presses
Press and hold the [*] key for 3 seconds
[*]
Enter the master code, followed by the [*] key
[1][2][3][4] [*]
Enter the value to change the relay pulse time, followed by the [*] key
[2][5] [*]
Enter the remote receiver ID that the transmitter will be taught to, followed by the [*] key
[1] [*]
Enter the relay number, followed by the [*] key
[1] [*]
Enter the pulse time in mmss, followed by the [*] key
[0][0][1][0] [*]
When complete press the [#] key
[#]
This will leave you in the remote receiver menu
This table shows the properties that can be
allocated to a button

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the IDS X16 and is the answer not in the manual?

IDS X16 Specifications

General IconGeneral
BrandIDS
ModelX16
CategorySecurity System
LanguageEnglish

Related product manuals