4. BOILER PIPE INSTALLATION
Horizantal chimney's duct and vertical chimney's pipe connections are very
important, therefore, it must be done carefully. Warranty of the smoke pipe
connection should be made accordingly.
The minimum safety opening surface sections should be 15%. Slope in the
horizontal section of the pipe should be 3-5%. (3-5 cm per meter). The horizantal
chimney's duct should not be longer than 2 m.
The stove chimney pipe outer diameter is 100 mm.
Horizantal chimney's duct and vertical chimney's pipe should be made of durable
materials for heat, corrosion and condensation.
Please take care of flue pipe standart sizes, the problems in case of using
nonstandard sizes will not be under our responsibility.
4.1 BOILER AND CHIMNEY WITH INSTRUCTIONS
The main cause of the chimney fire;
o Improper selection or pipe that dust is flammable fuel. In the event of
appropriate conditions can cause fires ignite in the channels.
o Ways of avoiding them; that the chimney should be cleaned at least 2 times per
year, depending on the fuel quality.
o That correct and appropriate chimney selection should be made. Ensuring that
the sealing and smoke in the chimney pipe and must be made in isolation.
Fresh air intake area of the ducts that maintaining and cleaning the boiler is
installed.
Surrounding the peak point of the roof of the chimney to the interference of the
obstacle (the ridge) from height must be at least 80 cm.
Should chimney's pipe inner diameter is 100 mm.
Chimney flue test should be performed before making connections. If the chimney
connections should be carried out after removal of the traction problem had this
problem in the chimney.