4. BOILER PIPE INSTALLATION
• Horizantal chimney's duct and vertical chimney's pipe connections are very
important, therefore, it must be done carefully. Warranty of the smoke pipe
connection should be made accordingly.
• The minimum safety opening surface sections should be 15%. Slope in the
horizontal section of the pipe should be 3-5%. (3-5 cm per meter). The horizantal
chimney's duct should not be longer than 2 m.
• The stove chimney pipe outer diameter is 100 mm.
• Horizantal chimney's duct and vertical chimney's pipe should be made of durable
materials for heat, corrosion and condensation.
• Please take care of flue pipe standart sizes, the problems in case of using
nonstandard sizes will not be under our responsibility.
4.1 BOILER AND CHIMNEY WITH INSTRUCTIONS
• The main cause of the chimney fire;
o Improper selection or pipe that dust is flammable fuel. In the event of
appropriate conditions can cause fires ignite in the channels.
o Ways of avoiding them; that the chimney should be cleaned at least 2 times per
year, depending on the fuel quality.
o That correct and appropriate chimney selection should be made. Ensuring that
the sealing and smoke in the chimney pipe and must be made in isolation.
• Fresh air intake area of the ducts that maintaining and cleaning the boiler is
installed.
• Surrounding the peak point of the roof of the chimney to the interference of the
obstacle (the ridge) from height must be at least 80 cm.
• Should chimney's pipe inner diameter is 100 mm.
• Chimney flue test should be performed before making connections. If the chimney
connections should be carried out after removal of the traction problem had this
problem in the chimney.