1.2 OPERATING INSTRUCTIONS
• This device should be installed in accordance with the related regulation and EU
standards.
• Pellet boiler has been produced in accordance with TS EN 303-5 standards.
• The pump flow should be in the direction of the return line.
• Automatic air prufier must be in the system.
• When the boiler is process of fire on, do not open the ash purge cover.
• You don’t put the any materials (foreign materials) in the pellet tank.
• Turbulator cleaning should be done once a week when the boiler turn off.
• Power supply should be used during long-term power outages.
• Boiler must be installed according to the installation schema.
• Boiler is not suitable for a shared chimney system.
• Pellet boiler must be installed as close as possible to the chimney. (chimney
connection must be shorter.)
• Boiler and chimney connector must be connected to an existing chimney or an
external double-walled chimney. Pipe inner diameter must be 100 mm.
• Extractor fan throw out the combustioned gas and chimney easily throw out the
smoke.
• Correct and efficient chimney system is necessary to throw out the smoke ( no
kick back and sending the smoke out of boiler in case of any blackout).
• Chimney cleaning cap must be under chimney pipe and cleaning must be done
from here.
• Chimney must cleaned minimum twice a year.
• The place where boiler must be equipped with:
o Electrical power 230V 50Hz. (EN 73-23)
o Grounding plug.
o If there is no ground connection it should be provided immediately.
o Fresh air must be provided from outside.
o Please, use the Voltage regulator for voltage fluctutaion.
•
Burning pot, ash box and air inlets should be cleaned.
•
Fuel should be checked if wet or not.
• 120 cm and longer radiator must be connected to the installation with a reverse
connection.
• Calorific boiler’s connections must be made with conical iron union.