Boiler is shutting down
automaticly.
The pellet tank may be empty
Fill the pellet tank at the appropriate
level
The ashtray cover may be open
check the ashtray cover
Bad pellet quality
You must use qualiy pellet
Pellet flow may be low
Check the pellet flow
Combustion room may be dirty
Clean the combution room
Pressure switch faulty
Change the pressure switch
The boiler runs a few
minutes and then the
switches off
Start-up isn’t completed
Rerun the Start-up
Power cut
Wait the otomatic start
Smoke of the duct
Clean the smoke duct.
Temperature sensor problem
Check the temperature sensor
The smoke evacution
motor does not work
Faulty of motor
Check the motor
Mainboard faulty
Change the mainboard
Broken kontrol panel
Change kontrol panel
Boiler is not powered
Check the fuse.
Pellets accumulate in the
combustion pot
Insufficient cobustion air
Clean the combustion pot and check
that all the holes are clear.