10-7
Alarm 2) (BDE Alarm bit display)
BDE Contents/Cause of alarm
Normal/
Abnormal
determine
value
Assumed breakdown unit Countermeasure
Compound judgment
etc. (If necessary. )
1
ADE communication
error
Communication error
between BDE-ADE is
occurred.
0;NORM
1;ALM
2
Core Module
communication error
Core Module communication
error is occurred
0;NORM
1;ALM
3
Handset
communication
error
Communication error
between BDE-Handset is
occurred
0;NORM
1;ALM
Poor connection of
Handset cable
Handset
BDE
Confirm the cable
connection
Replace Handset
Replace Board
4
Cable Calibration
error
ADE-FTU cable offset is
failed when JUE-500 is
activated.
0;NORM
1;ALM
Poor connection of
ADE-BDE cable
ADE-BDE cable loss is
abnormally large.
ADU
BDE
Confirm cable
connection
Replace Cable
Replace Board
5 Core Module reset
0;NORM
1;ALM
6
Core Module
communication error
Core Module does not
replay at AT level
0;NORM
1;ALM

Table of Contents