Nominal heat input kW (kcal/h) 25,5 (21914)
DHW minimum heat input kW (kcal/h) 7,6 (6578)
CH minimum heat input kW (kcal/h) 12,8 (11045)
Nominal heat output (useful) kW (kcal/h) 23,8 (20468)
DHW minimum heat output (useful) kW (kcal/h) 6,8 (5848)
CH minimum heat output (useful) kW (kcal/h) 11,5 (9847)
Eciency at 100% heat output % 93,4
Eciency at 30% nominal heat output load % 90,2
Heat loss at case with burner On/O % 0,60 / 0,46
Heat loss at ue with burner On/O % 6,00 / 0,03
Heating circuit max. working pressure bar 3
Heating circuit max. working temperature °C 90
Adjustable heating temperature °C 35 - 80
Total volume system heating expansion vessel l 4,2
Expansion vessel pre-charge bar 1
Generator water capacity l 0,7
Total head available with 1000 l/h ow rate kPa (m H
2
O) 30,4 (3,10)
Hot water production useful heat output kW (kcal/h) 23,8 (20468)
Domestic hot water adjustable temperature °C 35 - 55
Domestic circuit ow limiter at 2 bar l/min 7,1
Min. pressure (dynamic) domestic hot water circuit bar 0,3
Domestic hot water circuit max. working pressure bar 10
Minimum D.H.W. ow rate l/min 1,7
Specic ow rate (∆T 30°C) l/min 10,5
Continuous ow rate (∆T 30°C) l/min 11,1
Weight of full boiler kg 29,7
Weight of empty boiler kg 29
Electric attachment V/Hz 230/50
Nominal absorption A 0,67
Installed electric power W 135
Power absorbed by circulation pump W85
Power absorbed by fan W34
Equipment electrical system protection - IPX5D
NO
X
class -3
Weighted NO
X
mg/kWh 139
Weighted CO mg/kWh 61
Type of appliance
C12 /C32 / C42 / C52 / C62 /
C82 / B22 / B32
Category II2H3P / II2H3+
- Fume temperature values refer to an air inlet
temperature of 15°C.
- e data relevant to domestic hot water per-
formance refer to a dynamic inlet pressure of
2 bar and an inlet temperature of 15°C; the
values are measured directly at the boiler outlet
considering that to obtain the data declared
mixing with cold water is necessary.
- e max. sound level emitted during boiler
operation is < 55dBA. e sound level value is
referred to semianechoic chamber tests with
boiler operating at max. heat output, with
extension of fume exhaust system according
to product standards.
3.19 TECHNICAL DATA.