3.18 Casing removal.
To facilitate boiler maintenance the casing can be completely
removed as follows:
- remove the plastic lower protection grill;
- undo the screws (1) on the bottom of the casing front;
- pull the bottom of the casing front outwards while at the
same time pushing upwards (see g.);
- undo the screws (2) on the top of the casing front support
sheet (see g.);
- undo the screws (3) on the bottom side of the boiler then
push upwards lightly in order to free the side.
2
2
1
3
30
INSTALLERUSERTECHNICIAN