iDrive2 inverters Function Parameters
44
Function
code
Name
Detailed instruction of parameters
Default
value
Modify
BIT8:analog AI2 value(V on)
BIT11:current stage in multi-stage speed
BIT12:pulse counters
P07.08
Frequency
display
coefficient
0.01~10.00
Displayed frequency=run frequency* P07.08
1.00
P07.09
Rotation
speed
coefficient
0.1~999.9%
Mechanical rotation speed =120*displayed run
frequency×P07.09/motor pole pairs
100.0%
P07.10
Linear speed
displayed
coefficient
0.1~999.9%
Linear speed= Mechanical rotation speed×P07.10
1.0%
P07.11
Reserved
P07.12
Module
temperature
-20.0~120.0
P07.13
Software
version
1.00~655.35
P07.14
Local
accumulative
running time
0~65535h
P07.18
The rated
power of the
inverter
0.4~3000.0kW
P07.19
The rated
voltage of the
inverter
50~1200V
P07.20
The rated
current of the
inverter
0.1~6000.0A
P07.21
Factory bar
code 1
0x0000~0xFFFF
P07.22
Factory bar
code 2
0x0000~0xFFFF
P07.23
Factory bar
0x0000~0xFFFF