Pump & Motor Performance
The ve minute duty cycle must be adhered to. Operators have a choice of running the crane intermittently all
day, using the duty cycles per the S2 and S3 curves, or at full power for 4.5 minutes, which MUST be followed by
a complete cool-down to ambient.
180 AMPS
0
1
2
3
4
5
6
0.0
5.0
10.0
15.0
20.0
25.0
Q - 1.6 CC
I - 1.6 CC
0
50
100
150
200
300
250
0 500 1000 1500 2000 2500 3000 3500 4000 4500
PSI
BAR
0 25 50 75 100 125 150 175 200 225 250 275 300
2500 PSI
CAUTION
Avoid motor damage! Operate within
performance curves shown.