Questions and Answers

  • M
    matthew20Aug 16, 2025
    What to do if my InfiRay Thermal cameras riflescope can't connect to my smartphone or tablet?
    • C
      christopher26Aug 16, 2025
      If your InfiRay Thermal cameras riflescope can't connect to your smartphone or tablet, it could be due to a wrong Wi-Fi password. Ensure you input the correct password. Alternatively, too many Wi-Fi signals around the device may interfere with the connection. Try moving the device to an area with fewer Wi-Fi signals.
  • S
    Stephen HallAug 19, 2025
    How to fix an InfiRay Thermal camera riflescope that won't turn on?
    • H
      hendersontanyaSep 12, 2025
      If your InfiRay Thermal camera riflescope won't turn on, the batteries may be completely discharged. Charge the battery to resolve this issue.
  • T
    Tracey JohnsonAug 22, 2025
    Why won't my InfiRay Thermal camera riflescope work with an external power supply?
    • D
      Dr. Christopher BradleyAug 22, 2025
      If your InfiRay Thermal camera riflescope isn't working with an external power supply, the USB cable might be damaged. Try replacing the USB cable. Also, the external power source itself could be discharged, so check the external power source.
  • K
    Katie ScottAug 25, 2025
    How to fix a fuzzy image on InfiRay Thermal cameras?
    • C
      Christopher DeanAug 26, 2025
      If the image on your InfiRay Thermal cameras is fuzzy, not clear, or unbalanced, it indicates that calibration is required. Perform image calibration according to the Calibration section of this manual.
  • C
    Cynthia TaylorAug 28, 2025
    What to do if Wi-Fi signal is missing or interrupted on InfiRay Thermal cameras?
    • A
      Adam BennettAug 28, 2025
      If the Wi-Fi signal is missing or interrupted on your InfiRay Thermal cameras, the smartphone or tablet may be out of range of a strong Wi-Fi signal, or there may be obstacles. Replace the device until Wi-Fi signal is stable.
  • J
    John SanchezAug 31, 2025
    Why does the aiming reticle shift after firing rounds on my InfiRay Thermal cameras riflescope?
    • S
      singletonjimmyAug 31, 2025
      If the aiming reticle shifts after firing rounds on your InfiRay Thermal cameras riflescope, it may not be securely mounted, or the mount may not be fixed on the riflescope. Check that the riflescope has been securely mounted. Also, ensure you are using the same type and caliber of bullets as when the riflescope and weapon were initially zeroed. A slight shift is possible if the riflescope was zeroed in summer and is being used in winter, or vice versa.
  • G
    Gabriella SantanaSep 3, 2025
    How to brighten a dark image on InfiRay Thermal cameras?
    • S
      Sydney ScottSep 3, 2025
      If the image on your InfiRay Thermal cameras is too dark, the brightness level is likely too low. Adjust the screen brightness.
  • E
    Eric BrightSep 6, 2025
    How do I fix an InfiRay Thermal cameras riflescope that will not focus?
    • P
      Peggy StephensonSep 6, 2025
      If your InfiRay Thermal cameras riflescope will not focus, adjust the riflescope according to the Powering On and Image Setting section. Check the outer surfaces of the objective lenses and eyepiece and, where necessary, wipe them free of dust, condensation, frost, etc. In cold weather, you can use special anti-fogging coatings.
  • S
    seth15Sep 9, 2025
    What causes a clear GUI but a blurry image on InfiRay Thermal cameras?
    • P
      Paul MillsSep 9, 2025
      If the GUI is clear but the image is blurry on your InfiRay Thermal cameras, the lens is not focused. Adjust the image sharpness by rotating the lens adjuster.
  • L
    lisamartinezSep 12, 2025
    How to clean dust or condensate on InfiRay Thermal cameras lens?
    • J
      Janice GutierrezSep 12, 2025
      To clean dust or condensate on the lens of your InfiRay Thermal cameras, wipe off the outside optical surfaces with a soft cotton cloth. Allow the riflescope to dry by leaving it in a warm environment for 4 hours.

Summary

Important Safety Information

Safety Precautions and Handling

Covers environmental, swallowing, and operational safety guidelines for the device.

Technical Specifications

Technical Specifications (Continued)

Components and Controls

Description of Controls

Button Operations

Details the effect of short and long presses for Power, Zoom, Menu, and Photography buttons.

Battery Safety and External Power

Safety Precautions

Critical warnings for battery handling, charging, and usage to prevent damage or fire.

Operation and Mounting

Installation of Rifle Mount

Steps for attaching the rifle mount to the scope and weapon.

Device Operation and Zeroing

Power On and Image Settings

Guide to turning on the device and adjusting image parameters like brightness and contrast.

Zeroing Procedure

Detailed steps for the 'Freeze' zeroing method to align reticle with impact.

Zeroing Details

Zeroing - submenu Zeroing Distance

Setting zeroing distance and adjusting reticle to match impact point.

Calibration and Digital Zoom

Calibration Modes

Explains Automatic, Manual, and Background calibration modes.

Quick Menu Function

Quick Menu Options

Details how to change image mode, brightness, sharpness, and zeroing distance.

Main Menu Navigation

Main Menu Structure

Explains how to access and adjust options like Ultraclear mode.

Main Menu Functions: Wi-Fi, Mic, Calibration

Calibration Mode Selection

Selecting between Automatic, Manual, and Background calibration.

Main Menu Functions: Compass, Motion Sensor, Reticle

Reticle Settings

Options for setting zeroing profile, reticle type, and color.

Reticle Settings Details

Zeroing and Distance Settings

Zeroing Distance and Procedure

Setting zeroing distance and executing the zeroing function.

Zeroing Adjustments

Reticle Adjustment and Saving

Moving the reticle to match impact point and saving the settings.

Resetting Zeroing Distance

How to set a new zeroing distance value.

Standby and Range Reference Settings

Range Reference Setup

Setting effective range, target type, and height for ranging.

Range Reference Details and Pixel Correction

Pixel Correction and Compass Calibration

PIP Function and Rangefinding

Wi-Fi Functionality

Wi-Fi Setup and App Integration

Device Inspection and Maintenance

Trouble Shooting

Fault Diagnosis and Solutions

Provides a table of common issues and corrective actions for operation.

Troubleshooting Continued

Advanced Troubleshooting

Solutions for reticle shift, focus issues, and Wi-Fi connectivity problems.

Troubleshooting: Image Quality and Temperature Effects

InfiRay Geni Series Specifications

General IconGeneral
Pixel Size12 μm
Frame Rate25 Hz
Operating Temperature-20°C to +50°C
Storage Temperature-40°C to +70°C
Ingress ProtectionIP54
Spectral Range8-14μm
Display Resolution640x480
Battery TypeLi-ion

Related product manuals