65
Item
Function Command
Min
Max Return Note
9
Do auto image
(AIM1)
--
--
10
Get no signal power off timer
(AOT?)
--
--
(0-36,1)
11
Set no signal power off timer
(AOTn)
0
36
Timer = n x 5 minutes
12
Get Auto source value
(ASC?)
--
--
(0-1,1)
0: Off
1: On
13
Set auto source off / on
(ASC0)
0
1
14
Get blank status
(BLK?)
--
--
(0-1,1)
0: Off
1: On
15
Set blank off
(BLK0)
0
1
16
Get brightness value
(BRT?)
--
--
(0-100,50)
17
Set brightness value
(BRTn)
0
100
18 Get ceiling value (CEL?) -- -- (0-3,1)
0: Desktop Front
1: Desktop Rear
2: Ceiling Front
3: Ceiling Rear
19
Set ceiling value
(CELn)
0
3
20
Get close caption value
(CLC?)
--
--
(0-1,1)
0: Off
1: On
21
Set close caption value
(CLCn)
0
1
22
Get color saturation value
(CLR?)
--
--
(0-100,50)
23
Set color saturation value
(CLRn)
0
100
24 Get color temperature value (TMP?) -- -- (0-2,1)
0: Warm
1: Normal
2: Cold
25
Set color temperature value
(TMPn)
0
2
26
Get contrast value
(CON?)
--
--
(0-100,50)
27
Set contrast value
(CONn)
0
100
28
Get digital zoom value
(DZM?)
--
--
(-10-10,1)
29
Set digital zoom value
(DZMn)
-10
10
30 Get error item (ERR?) -- -- (0-9,1)
0: No error
1: Lamp
3: Ballast
4: Fan
5: Temp
7: case open
8: DMD
9: Color wheel
31
Factory reset (user)
(RST1)
--
--
32 Get Freeze status (FRZ?) -- -- (0-1,1)
0: Off
1: On
33
Set Freeze off
(FRZ0)
--
--
34
Set Freeze on
(FRZ1)
--
--
35 Get Gamma value (GTB?) -- -- (0-5,1)
0: 1.8
1: 2.0
2: 2.2
3: 2.4
4: B&W
5: Linear
36
Set Gamma value
(GTBn)
0
6
37
Get H position value
(HPS?)
--
--
(-5-5,1)
38
Set H position value
(HPSn)
0
5
39
Get Lamp Normal mode hours
(LMO?)
--
--
(0-9999,0)
40
Get Lamp Smart Eco mode hours
(LML?)
--
--
(0-9999,0)
41
Get Lamp Eco mode hours
(LME?)
--
--
(0-9999,0)
42
Reset lamp hours (User)
(LRT1)
--
--
43
Get current Lamp hours
(LMP?)
--
--
(0-9999,0)
44
Get lamp reset times
(LMR?)
--
--
(0-9999,0)

Table of Contents