1.3.2.2.1 USB device
iUR250 reader unit can be connected by type A USB.
1.3.2.2.2 Wake-up mechanism
iUR250 is design to save power thanks to a stand-by mode.
To wake-up iUR250, insert a card or use Wake-up mechanism.
Pin 2 of COM0 link drive the wake-up mechanism.
Wake-up pin state
Hz (high impedance)
Stand-by authorized
Drive to “0”
Wake-up / Stand-by unauthorized
The Wake-up pin is drive to “0” by the one asking the wake-up.
It could be driven by iUR250, iUP250 or any devices designed to be compliant (Host
device…).
PINPad
iUP 250
Card Reader
iUR 250
USB
COM0
1 - GND
2 - Wake-up
3
4
5
6
COM0 & 2
1 - GND
2 - Wake-up
3
4
5
6
USB
Any devices design to be compliant.
HZ => Stand-by
« 0 » => Wake-up
HZ => Stand-by
« 0 » => Wake-up
HZ => Stand-by
« 0 » => Wake-up