Intégration Guide_iUP250&iUR250 51/83 Copyright © 2012 Ingenico
900009151 R11 000 01/1223 All rights reserved
5 INSTALLATION PROCEDURE IN KIOSKS
Note: It is required to use ESD-protective clothing while handling these devices.
5.1 SECURITY REQUIREMENT
The integration must be done to be compliant with PCI requirement.
Payment Card Industry – PIN Transaction Security (PTS) - Modular Derived Test
Requirements Version 3.1 October 2011
Positioning of IUP250 on the unattended device must be in such way as to make
keypad spying difficult (according to PCI PTS - Modular Derived Test Requirements
Version 3.1 October 2011).
If the unattended device doesn’t provide such protection, an Ingenico privacy shield
option can be provided.
iUP250 and iUR250 must be mounted on the unattended machine as indicated in the
installation guide to activate removal detector.
CAUTION
NEVER ask the customer to divulge their PIN Code. Customers should be advised to
ensure that they are not being overlooked when entering their PIN Code.
5.2 KIOSK MECHANICAL REQUIREMENTS
The kiosk panel can be metallic or plastic.
The kiosk panel can be coated with painting but grounding of iUN modules must be
insured.
The kiosk panel thickness must be between 2 mm and 5 mm.
5.3 GENERAL INSTALLATION RECOMMENDATIONS
Installation requirements:
Ensure that you have enough free space for installation, operational and
maintenance needs.
Be aware of the safety regulations.
Carefully consider the general and local payment security requirements and
any impact they may have on the kiosk
Carefully consider the ergonomic aspects and also the local acts or
recommendations concerning disabled and visually impaired people.
See environmental specification and especially in case of very cold or humid
weather, take steps to ensure that the internal temperature is at least -20 °C.
5.4 KIOSK SUGGESTED LAYOUTS FOR IUR250 IUP250
In order to save space, keep good ergonomics and relative protection from
environment, we recommend the following configurations.