Installation manual
Installation 33
3-1-9
Maintenance status
The maintenance status is signaled on the keypads by the “Maintenance” message and the
address of the keypad. In the case of keypads with built-in readers, the address of the reader
(if enabled) will also be shown.
During service/maintenance mode, the control panel:
Forces the relay output on the motherboard (Table 2-7: Mother board - terminal board, 1-
2-3) to standby status.
Does not activate the outputs (and will force to standby any active outputs) triggered by:
•• alarm or zone/partition tamper
•• peripheral tamper
•• open/dislodged panel tamper
It allows initialization of the keypad address programming phase.
It allows initialization of the reader address programming phase.
Initializes automatically the auto-enrollment of the peripherals connected to the BUS at 10
seconds intervals. It allows assignment of the addresses to the peripherals connected to
the BUS and, at 10 second intervals, enrolls the peripherals it finds.
The control panel will not reset the BUS in an attempt to retrieve peripherals in the event
of peripheral loss.
It will continue to operate as normal, except under the aforesaid circumstances.
During service/maintenance mode, the Alien keypad:
Does not require user-code entry to access the sections which correspond to the “Settings”
key.
The first parameters shown in the “Settings - Alien” section are the addresses of the Alien
keypad and its built-in proximity reader and, only for the Alien/S, the status of tamper
enablement on the keypad.
It is not possible to access the “Climate” section.
The display shows the address of the Alien keypad and its built-in proximity reader in the
top left-hand corner of the home page.
The display shows the letters relating to the operating status of the partitions in the bottom
left-hand corner of the home page.
The control panel can be placed in maintenance mode by:
Inserting the Maintenance jumper in the “SERV” position.
Enabling the “Maintenance” option
USING THE
MAINTENANCE
JUMPER
The Maintenance jumper (Table 2-6: Mother board - description of parts, J) can be inserted in
two different positions:
“RUN” (control panel operating normally)
“SERV” (control panel ready for maintenance work)
THE
“MAINTENANCE”
OPTION
The control panel enters “Maintenance” mode when this option is enabled and exits
“Maintenance” mode when it is disabled. You can enable/disable this option at the keypad or
via computer.
Via keypad
1. Access the “Programming Panel options” section.
Type-in Code
(Installer PIN)
, PROGRAMMING Panel options .
2. Press to enable the “Maintenance” option, or to disable it.
3. Press
OK
to exit and save.
Via software
This option is made available by clicking on the Control panel parameters button in the
section on the left and accessing the “Programming” section on the right. The “Control panel
parameters” section provides the “Maintenance” option, click-on this option to enable/disable
it.
Mainten K03 P05
Armed Away mode
Keypad address
Reader address
“RUN”
position
“SERV”
position