12. No arc power change after [Arc Calibration]
An internal factor is calibrated and adjusted for the specic arc power selected.
The displayed arc power in each splice mode does not change.
13. Forget to put the optical ber during the process of maintenance function
It is invalid to press the return key. You need to open the wind cover and put the
prepared bers and press the “SET” or “RESET” button to continue
14. Fail to upgrade
When users use the "new" U-disk to upgrade, the splice may not be able to
correctly identify the upgrade program le; you need to reset the U-disk, and restart
the splicer.
Check whether the upgrade le name and the format are correct.
If you cannot solve the problems, please contact the manufacturer directly.
15. Others
Please refer to the training video in detail.