- 142 -
Group F8 Auxiliary Function
Jog running
frequency
Factory default
value
2.00Hz
F8-00
Setup range
0.00Hz ~ maximum frequency
Jog speed-up time
Factory default
value
20.00s
F8-01
Setup range 0.00s~ 6500.0s
Jog speed-down
time
Factory default
value
20.00s
F8-02
Setup range 0.00s~ 6500.0s
It is used to define the reference frequency and acceleration/deceleration
time of the driver when jogging. The Jog process is started and stopped
according to the start mode 0 (F6-00, direct start) and the stop mode 0 (F6-10,
deceleration time to stop).
The Jog acceleration time means the time required for the driver to
accelerate from 0Hz to the maximum output frequency (F0-10).
The Jog deceleration time means the time required for the driver to
decelerate from the maximum output frequency (F0-10)to 0Hz.
Speed-up time 2
Factory
default value
20.00s
F8-03
Setup range 0. 0s~ 6500.0s
Speed-down time 2
Factory
default value
20.00s
F8-04
Setup range 0.0s~ 6500.0s
Speed-up time 3
Factory
default value
20.00s
F8-05
Setup range 0.0s~ 6500.0s
Speed-down time 3
Factory
default value
20.00s
F8-06
Setup range 0.0s~ 6500.0s
Speed-up time 4
Factory
default value
20.00s
F8-07
Setup range 0.0s~ 6500.0s
F8-08
Speed-down time 4
Factory
default value
20.00s