- 42 -
C. DI Terminal Connection:
1 Connection with dry contact sharing the negative pole
Fig.3-11 Connection with dry contact sharing the negative pole
This is one of the most commonly used connection mode. If external power
supply is used, it must remove the short circuit copper bars between +24V and
OP respectively,which is determined by J11 jumper on the control board.
and connect the positive pole of external power supply to OP and negative
pole to CME.
Control board of servo driver