EasyManua.ls Logo

Inovance IS300 Series - Page 65

Inovance IS300 Series
211 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 59 -
Function
code
Name LED display Setup range
Minimu
m unit
Factory
default
value
Modific-
ation
descrip-t
ion
F0-01 Control mode Control mode
0: Speed sensorless
vector control (SVC)
1: Speed sensor
vector control (VC)
2:V/F control
1 1
F0-02
Command source
selection
Command
source selection
0: 0:Operation panel
running command
channel (LED OFF)
1: Terminal
command channel
(LED ON)
2: Serial port
command channel
(LED flashes)
1 0
F0-03
Main frequency
source X
selection
Frequency
source X
selection
0: Digital setup UP
and DOWN
adjustment
(non-recorded)
1: Digital setup UP
and DOWN
adjustment
(recorded)
2: Al1
3: Al2
4: Al3
5:Reserved
6: MS speed
7: Resvered
8: Resvered
9: Communication
setup
1 1