- 63 -
Function
code
Name LED display Setup range
Minimu
m unit
Factory
default
value
Modific-
ation
descrip-t
ion
F0-16
Carrier frequency
adjustment
selection
Carrier
frequency
adjustment
selection
0: Fixed PWM,
carrier frequency
temperature
adjustment is
inenabled
1: Random PWM,
carrier frequency
temperature
adjustment
inenabled
2: Fixed PWM,
carrier wave
temperature
adjustment valid
3: Random PWM,
carrier frequency
temperature
adjustment enabled
1 2
F0-17 Speed-up time 1 Speed-up time 1 0.0s6500.0s 0.1s 20.0s
F0-18
Speed-down
time1
Speed-down
time1
0.0s6500.0s 0.1s 20.0s
Group F1 Motor Parameters
F1-00
Motor type
selection
Motor type
selection
0: Common
asynchronous motor
1: Variable
frequency
asynchronous motor
2: Permanent
magnetic
synchronous motor
1 2
F1-01 Rated power Rated power 0.4kW1000.0kW 0.1kW