- 69 -
Function
code
Name LED display Setup range
Minimu
m unit
Factory
default
value
Modific-
ation
descrip-t
ion
F4-02
D13 terminal
function selection
DI3 terminal
selection
1 9
F4-03
D14 terminal
function selection
DI4 terminal
selection
13: MS speed
terminal 2
14: MS speed
terminal 3
15: MS speed
terminal 4
16:Speed-up time
selection terminal 1
17 Speed-up
/speed-down time
selection terminal
18:Main frequency
source switching
19: UP and DOWN
setup clear (terminal
and keyboard)
20: Running
command switching
terminal
21:
Speed-up/speed-do
wn time inenabled
22~23:Reserved
32: DC brake
command
33: External fault
normally closed input
41~47Reserved
48Servo pump PID
selection terminal 1
1 0