- 73 -
Function
code
Name LED display Setup range
Minimu
m unit
Factory
default
value
Modific-
ation
descrip-t
ion
F4-52
AI3 correction
voltage1
AI3 correction
voltage1
-9.999V9.999V 0.001V 2.000V
F4-53
AI3 sample
voltage2
AI3 sample
voltage2
-9.999V9.999V 0.001V 8.000V
F4-54
AI3 correction
voltage2
AI3 correction
voltage2
-9.999V9.999V 0.001V 8.000V
F4-55
F4-58
Reserved - - - -
Group F5 Output Terminal
F5-00 Reserved Reserved Reserved reserved reserved
F5-01
Control board
relay
(T/A1-T/B1-T/C1
) output
selection
Control board
RELAY1 output
selection
1 2
F5-02
Control board
relay
T/A2-T/C2
output selection)
Control board
RELAY2 output
selection
0: No output
1: Servo driver is
running
2: Fault output
3: Frequency level
detection FDT output
4: Frequency arrival
5: In zero speed
operation
6: Motor overload
pre-warning
7: Servo driver
overload
pre-warning
8~11: Reserved
12: Running time
arrival
1 1