5 Parameter Table
- 32 -
Para� No� Para� Name Setting Range Unit Default Property
F5-10 AO1 function selection 0: running frequency
1: frequency reference
2: output current
3: output torque
4: output power
5: output voltage
6: reserved
7: AI1
8: AI2
9: AI3
10: feedback speed
11: feedback pressure
14: by communication control
12 to 16: reserved
1 10
☆
F5-11 AO2 function selection 1 11
☆
F5-14 AO1 offset factor -100�0% to 100�0% 0�1% 0�0%
☆
F5-15 AO1 gain -10�00 to 10�00 0�01 1�00
☆
F5-16 AO2 offset factor -100�0% to 100�0% 0�1% 0�0%
☆
F5-17 AO2 gain -10�00 to 10�00 0�01 1�00
☆
F5-23 AO1 measured value 1 -9�999 to 9�999 V 0�001 V 2�000 V
☆
F5-24 AO1 calculated value 1 -9�999 to 9�999 V 0�001 V 2�000 V
☆
F5-25 AO1 measured value 2 -9�999 to 9�999 V 0�001 V 8�000 V
☆
F5-26 AO1 calculated value 2 -9�999 to 9�999 V 0�001 V 8�000 V
☆
F5-27 AO2 measured value 1 -9�999 to 9�999 V 0�001 V 2�000 V
☆
F5-28 AO2 calculated value 1 -9�999 to 9�999 V 0�001 V 2�000 V
☆
F5-29 AO2 measured value 2 -9�999 to 9�999 V 0�001 V 8�000 V
☆
F5-30 AO2 calculated value 2 -9�999 to 9�999 V 0�001 V 8�000 V
☆
Group F6: Stopping
F6-10 Stopping mode 0: deceleration to stop
1: coast to stop
1 0
☆
Group F7: Keypad and Display
F7-02 The function of stop/reset key on
keypad
0: only the key can stop motor
1: in terminal control, the key can stop motor
2�in terminal control, the key can reset fault
3: in terminal control, the key can stop motor
and reset fault
1 2
☆
F7-06 Load linear speed display factor 0�0001 to 6�5000 0�0001 1�0000
☆
F7-07 IGBT temperature -1000°C to 1000°C 1°C ●
F7-09 Total running time 0 to 65535 h 1 h - ●
F7-10 Firmware version 1 - - - ●
F7-11 Firmware version 2 - - - ●
F7-12 Temporary rmware version 1 - - - ●
F7-13 Temporary rmware version 2 - - - ●