Function
Code
Parameter Name
Setting Range
Unit
Default
Commission
F4-10
DI filter time
0.000 to 1.000
s 0.010
F4-35
DI1 delay time
0.0 to 3600.0
s 0.0
F4-36
DI2 delay time
0.0 to 3600.0
s 0.0
F4-37
DI3 delay time
0.0 to 3600.0
s 0.0
F4-38
DI active mode
selection
7-segment
0
0
0
0
0
00000
N.A.
DI 5 active mode
0: High level active
ƿ
1: Low level active
ƿ
DI 4 active mode
0: High level active
1: Low level active
DI 3 active mode
0: High level active
1: Low level active
DI 2 active mode
0: High level active
1: Low level active
DI 1 active mode
0: High level active
1: Low level active
ƿ
: ‘High level active’ means that, if a high level voltage is applied to DI terminal, the DI signal will be seen as active.
‘Low level active’ means that, if a low level voltage is applied to DI terminal, the DI signal will be seen as active.